Cause analysis of steel leakage between plates during rapid replacement of submerged nozzle
The causes of steel leakage between plates during continuous casting quick change submerged nozzle are analyzed. The results show that the main causes of steel leakage between plates of submerged entry nozzle are related to factors such as nozzle surface oxidation, slow extension speed of quick change cylinder and unreasonable operation of nozzle change.?
According to the analysis results, corresponding control measures
are formulated, including improving the layout of argon pipeline in
tundish, By improving the extension speed and installation accuracy of
the quick change cylinder, improving the oxidation resistance of the
nozzle surface, optimizing the baking process of the submerged nozzle,
changing the nozzle operation and increasing the argon sealing flow,
the annual steel leakage between plates of the caster is finally reduced
from an average of 4 times to 0 times, and a good control effect is
achieved.